top of page
48dfc860acc24c05cf83ac483dc00b97.png

Storage HyC

The commercial/industrial hydrogen energy storage system covers medium to large-sized projects. It is combined with commercial photovoltaic systems, covering a power range of 50 kW to 1 MW.

It is suitable for:

  • Energy communities and residential areas

  • Hotels and shopping malls

  • Power generation in islands or isolated areas

  • Backup for data centers and other applications

  • Storage for photovoltaic parks and subsequent energy feed into the grid or direct sale of renewable hydrogen

The system is designed with flexibility and modularization, which can adjust the power according to the actual needs of customers and customize the design according to application scenarios.

System Advantages and Technical Features

COMMERCIAL SOLUTION.png

Integrated EMS

The system integrates hydrogen production, charging and control of fuel cell cogeneration. It not only improves the cooperation between system modules, but also simplifies the system control structure and reduces costs. In addition, the control system also supports remote monitoring, remote start and stop, and power regulation.

Highly integrated modular design

The system is divided into three parts: hydrogen production container, hydrogen storage container and fuel cell container and EMS.

High level explosion protection design

The system is divided into three parts: hydrogen production container, hydrogen storage container and fuel cell container and EMS.

Cold start design

The system includes a cold start unit, which can achieve quick start at -20℃. This improves the product's adaptability for use in cold areas, such as the north.

System Advantages and Technical Features

Hydrogen generating condition

2.jpg

Fuel cell operation condition

3.jpg

Product Features

LOW CONSUMPTION

Energy storage on the power generation side and peak shaving and valley filling on the power grid side“
The issue of improving the consumption of renewable energy

IMPROVE UTILIZATION

Flatten the volatility, timeliness, and seasonality of renewable energy Greatly improving its utilization rate

REDUCE DISTRIBUTION COSTS

Reduce the cost of grid installation and transmission and distribution in remote areas

REDUCE DISTRIBUTION COSTS

Zero carbon emissions throughout the entire process
Byproduct heat can solve users' heating problems

Product Feature

Item
Description
Parameters
Electrolyzer(PEM)
Nominal hydrogen production
5-50 Nm3/H
Pressure
0-3MPa
Nominal DC Consumption
<5kWh/Nm3 H2
Fuel Cell Module
Nominal Electrical Power
50kW-1MW
Nominal Thermal Power
40kW - 900kW
Hot water outlet temperature
60 ºC ~ Máx. 65 ºC
Hydrogen Storage
Hydrogen storage capacity
Custom Designed
Hydrogen Storage Type
20MPa cylinder/Hydrogen tank/Hydrogen container
Electric
Power Quality
380 VCA, 3P
Frequency
50Hz
Connecting
Power Off/On Network Connection Optional